Features :


  • Ingenious block construction, combined with powerful Peltier cooler, produces very rapid heating and cooling
  • Dry temperature control system maintains a clean and vibration-free working environment
  • With the rapid heat-up capability of the PCH, the DNA denaturation temperature of 95ºC is quickly reached. An audible alarm signals denaturation time-up, and the samples can then be rapidly cooled again, ready to load the electrophoresis gels.
  • A 2-line LCD display clearly indicates both set and actual values for temperature and time. Works in combination with simple push buttons for easy set-up.
  • Flexible tube sizes and rapid heat-up/cool-down times enables swift change of application
  • Block holds a combination of two microtube sizes simultaneously – up to a total of 32 tubes: 12 x 1.5 ml plus 20 x 0.5 ml

Specifications :

Temperature setting range   ºC -10 to 100
Temperature control range
ºC 30ºC below ambient to 100ºC
Stability   ±ºC 0.2
Uniformity @10ºC ±ºC 0.5
Setting resolution   ºC 0.1
Heat-up rate RT to 100ºC ºC/min >10
Cool-down rate 100ºC to RT ºC/min >10
  RT to -10ºC ºC/min >2
Capacity microtubes   12 × 1.5ml plus 20 × 0.5ml
Overall dimensions w/d/h mm 225/195/161
Input voltage   V   dc 12 via 110/230 universal power adaptor
Input type     ac (50 – 60Hz)
Input current   A 0.5


Download




Dry Block Heating/Cooling System PCH-1
Enlarged View
Dry Block Heating/Cooling System PCH-2

Dry Block Heating/Cooling System PCH-2

Features :

  • Ingenious block construction, combined with powerful Peltier cooler, produces very rapid heating and cooling
  • Dry temperature control system maintains a clean and vibration-free working environment
  • With the rapid heat-up capability of the PCH, the DNA denaturation temperature of 95ºC is quickly reached. An audible alarm signals denaturation time-up, and the samples can then be rapidly cooled again, ready to load the electrophoresis gels.
  • A 2-line LCD display clearly indicates both set and actual values for temperature and time. Works in combination with simple push buttons for easy set-up.
  • Flexible tube sizes and rapid heat-up/cool-down times enables swift change of application
  • Block holds up to 20 x 1.5 ml tubes

Specifications :

Temperature setting range   ºC -10 to 100
Temperature control range

30ºC  below ambient to 100ºC
Stability   ±ºC 0.2
Uniformity @10ºC ±ºC 0.5
Setting resolution   ºC 0.1
Heat-up rate RT to 100ºC ºC/min >10
Cool-down rate 100ºC to RT ºC/min >10
  RT to -10ºC ºC/min >2
Capacity microtubes   20 × 1.5ml
Overall dimensions w/d/h mm 225/195/161
Input voltage   V   dc 12 via 120/230  universal power adaptor
Input type     ac (50 – 60Hz)
Input current   A 0.5


Download








Contact Us
BioLinx India
Mr. Girish Nair . (Director)
106, Indirajeet Apts ,Behind Marathi School, Majiwada, Thane , Maharashtra
Mumbai - 400601, Maharashtra, India

Contact via E-mail

Contact via SMS



HomeProfileWhat We OfferSite MapContact Us
Member IndiaMART.com © BioLinx India. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code: